联系我们

公司名称:XXX

电话:XXX

手机:XXX

联系人:XXX

地址:XXX

新闻动态
外门窗质量控制性能要求
外门窗质量控制性能要求
Performance requirements for quality control of external windows and doors
一、密闭性要求
1. Airtight requirements
1.角部密封条(胶角):密封条应避免转角拼接,应将转角处密封条设计成90度整体式胶角。
1. corner seal (glue angle): the sealing strip should avoid the angle splicing, and the sealing strip at the corner should be designed as the 90 degree integral glue angle.
2.框扇密封条:开启扇部位宜设计三道密封胶条,分别为主密封胶条、扇压边胶条和框压边胶条。
2. frame fan seal: the opening part of the fan should be designed with Three sealants, which are mainly sealant, fan edge adhesive strip and frame press.
二、防渗漏要求
Two, anti leakage requirements
1.外窗必须设置排水通道、排水口、排气孔(气压平衡孔),排出窗框扇内积水。排水口外侧应设扣盖,防止强风将雨水、灰尘吹入窗扇。
1. outside window must set drainage channel, drain hole, exhaust hole (air pressure balance hole), discharge window frame fan to accumulate water. On the outside of the drain, a buckle cover should be set to prevent the strong wind from blowing rain and dust into the window.
2.隔热条应采用C型构造,与内外铝型材复合后在同一个水平面上,避免隔热条处积水造成渗漏、腐蚀隐患。同时可增加隔热条长度,提高热工性能。
2. heat insulation strip should be C type structure, combined with the internal and external aluminum profiles on the same horizontal surface, to avoid water leakage at the heat insulation strip and cause the hidden corrosion. At the same time, the length of the heat insulation strip can be increased, and the thermal performance can be improved.
3.门窗洞口尺寸:结构洞口预留不应过大,避免封堵困难造成渗漏隐患。
3. door and window hole size: the opening of the structure hole should not be too large to avoid the trouble of sealing.
4.企口:窗洞因为特殊原因,如外墙为石材幕墙,洞口预留尺寸大,结构洞口建议做企口,企口应与混凝土墙同时浇筑。
4.: window openings due to special reasons, such as exterior wall stone curtain wall, the hole reserved for large size, the structure recommended groove, groove should be pouring concrete wall and at the same time.
5.外窗台板:外墙材料为涂料的建筑,建议采用金属窗台板。金属窗台板内侧应压入窗框,外侧突出墙面做滴水。
5. outer window plate: the exterior wall material is the paint of the building, it is recommended to use the metal sill board. The inside of the metal window plate should be pressed into the window frame, and the outside of the panel should be made of the wall to make dripping water.
6.窗框与结构洞口:窗框宜立中安装,如靠外侧安装,应向内收进20mm,防止结构施工误差导致窗框安装在结构外皮以外,造成雨水渗漏。
6., window frames and structural openings: installation of window frames should be erect. If installed on the outside side, 20mm should be inward, so as to prevent structural construction errors and cause window frames to be installed outside the structural skin, causing rainwater leakage.
三、 框扇结构要求
Three, frame fan structure requirements
组角:组角是关系到门窗整体性的重要工序。
Group angle: the angle of the group is an important process which is related to the integrity of the doors and windows.
抹胶工艺:一般情况下应采用角码+抹组角胶工艺,窗角禁止未抹胶即挤压成型。
Gumming process: the corner angle + glue process should be put under normal circumstances, the corner of the window do not wipe glue that is extrusion molding.
注胶工艺:组角亦可采用角码+导胶槽+注胶孔+双组份注胶+角片工艺,保证角部强度要求,确保门窗成品在运输、安装后无变形移位现象的出现。
Plastic injection process: angle can be used to bracket two-component glue injection + process + Guide + glue groove angle + plastic injection hole, ensure the corner strength, make sure the doors and windows products in the transportation and installation of no deformation after shift phenomenon.
四、保温隔热要求
Four. Requirements for heat insulation and heat insulation
型材的腔体设计:型材应采用多腔体结构,减少热量的流失,同时应使外窗隔热构件上下共面,形成整体隔热面,消除冷桥,阻断热量流失通道。
The design of the section cavity is that the section should adopt multi cavity structure to reduce the heat loss, and at the same time, we should make the outer window insulation components face up and down to form the overall heat insulation surface, eliminate the cold bridge and block the heat loss channel.
2.玻璃安装槽内宜安装隔热胶条:增加空气腔室的数量,降低中空玻璃四周与型材之间的热量损失,提高整窗的保温效果。
2., the heat insulation strips should be installed in the glass installation slot: increase the number of air chambers, reduce the heat loss between the insulating glass and the profiles, and improve the insulation effect of the entire window.
3.窗扇应采用T型隔热条设计:窗扇隔热条设计为T型,与中间胶条搭接,实现扇框连接处冷热分区。禁止将中间胶条直接搭在扇的铝型材上。
The 3. window sash should be designed by T type heat insulation strip: the window fan insulation bar is designed to be T type, and it is connected with the middle glue bar to realize the cold and hot zoning of the connection of the fan frame. No intermediate strip directly on the aluminum on the fan.
4.隔热条应采用聚酰胺66(即Polyamide66,俗称尼龙66)。
4. heat insulation strip should be polyamide 66 (Polyamide66, commonly known as nylon 66).
5.玻璃暖边条:双层中空玻璃空腔四周宜设置暖边条,阻断玻璃空腔散热通道。
5. glass of warm edge: double hollow glass cavity should be set around the warm edge, blocking the glass cavity cooling channel.
6.在传热系数要求高的地域,可根据项目定位,在型材隔热腔体内增加保温隔热材料,满足K值要求。
6. in the region where the heat transfer coefficient is high, the thermal insulation material can be added to the body heat insulation cavity to meet the K requirements according to the location of the project.
7.外门:住宅首层住户通向花园的外平开门应设门槛,禁止不设门槛,门底部用毛刷封闭。住宅首层住户通向花园的双扇平开外门,关闭后两扇应咬合搭接,禁止中间留缝用毛刷封闭。
7. doors: open the door outside the first floor tenants to the garden house should set the threshold, do not set the threshold, the bottom of the door closed with a brush. The first floor of residential tenants to the garden door double flat open door, shut down after the two fan should bite the lap, middle seam with brush seal ban.
五、安全技术要求
Five. Safety technical requirements
1.玻璃扣条:玻璃扣条应安装在室内一侧,禁止将内开窗翻转成外开窗使扣条安装在室外一侧,保证防盗、安全、玻璃更换的要求,不留渗漏隐患。
1. glass fastener: the glass buckle should be installed on the indoor side. It is forbidden to turn the inside window into the open window, so that the button can be installed on the outdoor side, so as to ensure the requirements of theft prevention, safety and glass replacement, without leakage risk.
2.锁点:为提高外窗抗风压强度及防盗性能,外窗应采用多点锁。锁点设置应满足五金厂家设计安装手册要求。
2. lock points: in order to improve the anti wind pressure strength and anti-theft performance of the outer window, the outer window should adopt multiple lock. The lock point setting should meet the requirements of the hardware manufacturer's design and installation manual.
3.单元入口外门尺寸不应过大,以保证合页等五金配件的可靠性,避免产生安全事故。
The 3. unit entrance door size should not be too large, to ensure the reliability of hinges and other hardware accessories, to avoid the occurrence of safety accidents.
第二部分:建筑外门窗质量控制施工要求
The second part: the construction requirements for the quality control of the outside doors and windows of the building
六、附框施工
Six, frame construction
1.附框外侧与墙体间的缝隙应均匀,宜控制在10~15 mm。附框采用固定安装位置应满足:角部的距离不应大于150mm,其余部位的固定片中心距不应大于500mm,固定点与墙休固定点的中心位置至墙体边缘距离不应小于50mm。
The gap between the outside of the 1. frame and the wall should be uniform, and it should be controlled at 10~15 mm. The location of the attached frame should be fixed: the distance between corners should not be greater than 150mm, and the center distance of the rest pieces should not be greater than 500mm. The distance between the fixed point and the center of the rest point of the wall to the edge of the wall should not be less than 50mm.
2.附框塞口:钢副框与主体结构之间缝隙应采用干硬性水泥砂浆填塞,确保密实、严禁采用发泡剂填充。外侧做“α角(八字)”。涂刷1.2厚防水涂料。
2. frame plug mouth: the cracks between the steel auxiliary frame and the main structure should be stuffed with dry cement mortar to ensure the dense and strictly forbidden to be filled with foaming agent. Do "alpha angle" on the outside. Paint 1.2 thick waterproof coating.
七、主框扇安装施工
Seven. The installation of the main frame fan
主框与窗扇在工厂加工完成并组装,可以提高加工精度,从而提升整窗的气密性、水密性。
The main frame and the window sash are finished and assembled in the factory. The machining precision can be improved and the air tightness and water tightness of the whole window can be improved.
1.塞口完成后,按设计图纸检查核对窗规格、型号开启形式、开启方向、安装孔方位及组合附件等,如发现有变形者严禁安装上墙。
After completion of the 1. stopper, check the checking window specification, type opening mode, opening direction, installation hole orientation and combined accessories according to the design drawings, if the deformable persons are found, it is strictly prohibited to install the upper wall.
2.用规整的垫片保证铝合金窗框与钢副框之间间隙≤10,并使周边间隙均匀。
2. regular gaskets guaranteed between Aluminum Alloy frame and steel sub frame gap is less than 10, and the surrounding gap even.
3.校核铝合金窗框的正侧面的垂直度、水平度对角线,合格后及时进行报验及评定。
3. check Aluminum Alloy positive side of the window frame verticality and levelness of the diagonal, after passing the inspection and evaluation in a timely manner.
4.主框清理和打外框胶
4. main frame cleaning and framed glue
4.1.按规定领用指定颜色的中性硅酮耐厚密封胶将墙与门窗连接部位10mm范围用毛刷、干布清扫干净,贴好美纹纸,打胶,并用手或工具抹平,撕下美纹纸,进行局部调整。
According to the regulations, 4.1. is required to use the neutral silicone resistant thick sealant with specified color to clean up the 10mm area between the wall and doors and windows, brush and dry cloth, paste the beautiful paper and glue, and smooth it with hands or tools, tear the beautiful paper and make partial adjustment.
4.2.注意:外墙为涂料饰面时,外框胶应与涂料基层粘结;外墙饰面为石材、墙砖、铝板材料时,外墙饰面材料不能
4.2. note: when the external wall is used for coating, the outer frame adhesive should be bonded with the coating base. When the exterior wall facing is stone material, wall brick and aluminum plate material, the exterior wall facing material can not.

联系方式

  1. 公司名称:XXX
  2. 电话:XXX
  3. 手机:XXX
  4. 联系人:XXX
  5. 地址:XXX

版权 © 石家庄市门窗厂 网址:http://sjzmenchuang.89ix.com  推荐:石家庄断桥铝门窗,石家庄市阳光房,石家庄肯德基门

网站建设及优化保定遨游网络公司