3.1 安装玻璃前,将裁口内的污垢清除干净,并沿裁口的全长均匀抹1~3mm厚的底油灰。
3.1 before installing glass, dirt cutting mouth clean, and is cut along the mouth evenly with 1~3mm thick bottom putty.
3.2 安装长边大于1.5m或短边大于1m的玻璃,用橡胶垫并用压条和螺钉镶嵌固定。
3.2 installed long side more than 1.5m or the short side is larger than that of 1m glass, with a rubber pad and inlaying strip and screw.
3.3 安装于竖框中的玻璃,应搁置在两块相同的定位垫块上,搁置点离玻璃垂直边缘的距离宜为玻璃宽度的1/4,且不宜小于150mm。
3.3 installed on the frame of the glass, we should lay aside in the two block of the same location of the pad, aside from the edge of the glass vertical distance appropriate for the width of glass 1/4, and should not be less than 150mm.
3.4 安装于扇中的玻璃,应按开启方向确定其定位垫块的位置。定位垫块的宽度应大于所支撑的玻璃件的厚度,长度不宜小于25mm,并应符合设计要求。
3.4 fan installed in the glass, in the opening direction to determine the position of the locating block. The width of the positioning pad should be larger than the thickness of the supported glass, and the length should not be less than 25mm, and it should meet the design requirements.
3.5 玻璃安装就位后,其边缘不得和框、扇及其连接件相接触,所留间隙应为2~3mm。
3.5 glass after installation, and not the edge frame, fan and its connection with the contact, the gap should be 2~3mm.
3.6 玻璃安装时所使用的各种材料均不得影响泄水系统的通畅。
All materials used in the installation of the 3.6 glass shall not affect the patency of drainage system.
3.7 玻璃镶入框、扇内,填塞填充材料、镶压线条时,应使玻璃周边受力均匀。
3.7 glass inlay box, fan, packing materials, filling with pressure lines, should make the glass surrounding uniform stress.